| Items |
Characteristics |
| Operating temperature range |
-55℃--+105℃ |
| Rated electrostatic capacity range |
220--2700uF |
| Rated voltage |
6.3--35V.DC |
| Capacitance tolerance |
±20%(25℃ 120Hz) |
| Leakage current(uA) |
1≤0.01CVor3uA Larger C:Nominal capacity(Uf) V:Rated voltage(V) Reading after 2 minutes |
| Loss angle tangent value(25±2℃ 120Hz) |
Rated voltage(V) |
6.3 |
10 |
16 |
25 |
35 |
| tg |
0.26 |
0.19 |
0.16 |
0.14 |
0.12 |
| If the nominal capacity exceeds 1000 uF, for each additional 1000 uF, loss angle tangent increased by 0.02 |
| Temperature characteristic(120Hz) |
Rated voltage(V) |
6.3 |
10 |
16 |
25 |
35 |
| Impedance ratio Z(-40℃)/ Z(20℃) |
3 |
3 |
3 |
3 |
3 |
| Durability |
In an oven at 105 ℃, apply the rated voltage for a specified time, and then place it at room temperature for 16 hours before testing. The test temperature is 25± 2 ℃. The performance of the capacitor should meet the following requirements |
| Capacity change rate |
Within ± 30% of the initial value |
| Loss angle tangent value |
Below 300% of the specified value |
| Leakage current |
Below the specified value |
| High temperature storage |
Store at 105 ℃ for 1000 hours, and then test at room temperature for 16 hours. The test temperature is 25 ± 2 ℃. The performance of the capacitor should meet the following requirements |
| Capacity change rate |
Within ± 20% of the initial value |
| Loss angle tangent value |
Below 200% of the specified value |
| Leakage current |
Below 200% of the specified value |